Patch name | Company | Headquarters | Reference | Commercially available | Mode | Maximum duration | Cloud platform | Real-time connectivity |
---|---|---|---|---|---|---|---|---|
Zio XT | iRhythm technologies | San Francisco, USA | Barrett P et al. 2014 [3] | Yes | Continuous recording | 14 days | No | No |
Seeq | Medtronic | Tolochenaz, CH | Engel JM et al. 2015 [4] | No | Loop recording | 7 days | Yes | Yes |
Carnation Ambulatory Monitor | Bardy Dx | Seattle, USA | Rho R et al. 2018 [5] | Yes | Continuous recording | 7 days | Yes | Yes |
SmartCardia | SmartCardia | Lausanne, CH | − | Pending | Continuous recording | 14 days | Yes | Yes |
Finding | Points |
---|---|
Abnormal ECG* and/or heart disease** | +3 |
Palpitations before syncope | +4 |
Syncope during effort | +3 |
Syncope in supine position | +2 |
Autonomic prodromes*** | −1 |
Predisposing and/or precipitating factors**** | −1 |
Score | Interpretation | Mortality at 21–24 months |
---|---|---|
≥3 | Cardiac syncope likely (95% sensitive) | 17% |
<3 | Cardiac syncope less likely | 3% |
Item | Points |
---|---|
Age >65 years | +1 |
Cardiovascular disease in clinical history* | +1 |
Syncope without prodrome | +1 |
Abnormal ECG** | +1 |
Score | Mortality |
---|---|
0 points | 0% |
1 point | 0.8% |
2 points | 19.6% |
3 points | 34.7% |
4 points | 57.1% |